Sign In | Join Free | My chinapackagenet.com
China Guangzhou Rongtao Medical Tech LTD. logo
Guangzhou Rongtao Medical Tech LTD.
To be the top preferred ultrasound service company worldwide!
Verified Supplier

5 Years

Home > Ultrasound Probe Repair >

GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement

Guangzhou Rongtao Medical Tech LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement

Brand Name : GE

Model Number : RAB4-8-D

MOQ : 1

Price : Negotiable

Payment Terms : T/T,Western Union

Delivery Time : 1-5 work days

Packaging Details : Neutral Package

Category : Diagnostic medical device service

Description : Probes repair

Service : Repair Service for probes

Warranty : 60 days after fixed

Condition : Original

Purpose : Diagnosis for ultrasound

Contact Now

Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes

Crystal damage -Weak, dead, or damaged crystals

Very often the cause of crystal damage in ultrasound probes is the dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak elements cause the faint little lines that won’t obscure much. These are the first signs that the elements are getting progressively damaged and need to be replaced. Instead of faint lines if the lines are thick and pronounced, the elements are dead. If there are thick lines in the scanned image, important things can be missed out during diagnosis. You may be harming the patient due to misdiagnosis.

Solution

Repair/Replace the Crystal




GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement

Other hot GE models we can repair:

GE C1-5-D
GE C1-5-RS
GE 4C
GE 4C-RS
GE 4C-A
GE 4C-D
GE 4C-SC
GE E8C/E8C-RS
GE E8CS
GE RIC5-9-D
GE 3CRF-D
GE C1-6-D
GE RAB4-8-RS
GE RAB2-5-RS
GE 6S-RS
GE 12L-RS
GE 3SC-RS
GE L6-12-RS
GE 11L
GE 11L-D
GE 12L-RS
GE 8C
GE 3S
GE 3S-RS

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

Common ultrasonic probe damage Solutions
Lens damage, wear, holes, swelling, delamination Lens replacement
Strain relief damage, separation Strain replacement
Nosepiece and probe separation and cracks

Cosmetic repairs

Cable cuts Cable patches, possible cable replacement
Connector housing electrical damage Major and minor electrical repairs, pin module replacement

Probe Troubleshooting Summary
1.Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again
2.Lens and crystal failure are sometimes similar, both are shadowing on the image
3.If there is a single probe problem, replace the socket to have a check.
4.The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

Easy Ultrasound Transducer Maintenance Tips & Damage Prevention

Shipping

If possible, use the box/case/foam from the manufacturer to protect the ultrasound probe during the shipping process.

Storage

Do not store in clamp control housing, which puts unneeded stress on the cord and strain relief. Instead, keep unused ultrasound probes in a cool, dry place — ideally in a case or box.

Use

Check the ultrasound transducer before each use to make sure all elements are properly functioning.

Cleaning

Before submerging the probe, make sure the strain relief and cord are undamaged. Don’t leave the ultrasound probe in contact with cleaning solutions for extended periods.




Product Tags:

GE RAB4 8 D Ultrasound Probe Repair

      

Crystal Replacement Ultrasound Probe Repair

      
China GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement wholesale

GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Rongtao Medical Tech LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)